- The double-sided paneling is made of KRAFT paper.
- The core of the board is made of rigid polyisocyanurate foam (PIR) with very good insulating and fire retardant properties.
- The edges are milled to facilitate installation and improve thermal insulation. Milling can be performed as follows: FIT – straight edges, LAP – stepped, TAG * – tenon and groove.
* The surface of the cut slab is reduced by 15m.
1
Type of core
Rigid polyisocyanurate foam (PIR)
2
Filler density [kg / m3]
30 ( +6 / -2 )
3
Declared heat transfer coefficient λ D[W/m*K]
λ D = 0,026 for thickness: 20 – 79 mm
λ D = 0,025 for thickness: 80 – 119 mm
λ D = 0,024 for thickness: ≥ 120 mm
4
Coating
KRAFT paper with waterproofing impregnation
5
Plate dimensions [mm]
600 x 1200; 1200 x 2400
6
Available slab sizes on request [mm]
1000 x 1200; 1200 x 1200; 1800 x 1200; 1200 x 3000
7
Types of milling *
FIT – Straight edges, LAP – Stepped *, TAG – Thorn groove *
8
Thickness [mm]
from 20 to 250 mm
9
Plate thickness [mm]
20
40
50
60
80
100
120
150
180
200
220
250
40
50
60
80
100
120
150
180
200
220
250
10
Thermal resistance R D [m2*К/W]
0,75
1,15
1,90
2,30
3,20
4,00
5,05
6,30
7,55
8,40
9,25
10,50
1,15
1,90
2,30
3,20
4,00
5,05
6,30
7,55
8,40
9,25
10,50
11
Heat transfer coefficient U [W/m2*K]
1,30
0,65
0,52
0,43
0,31
0,25
0,20
0,16
0,13
0,12
0,11
0,10
0,65
0,52
0,43
0,31
0,25
0,20
0,16
0,13
0,12
0,11
0,10
12
Certificates and Protocols
Conclusion of the sanitary and epidemiological examination, Toxicity – T2, Fire spread – RP1, Flammability – B1
13
Compressive strength
≥ 120 kPa
* milling: LAP and TAG – the surface of the slab coatings is reduced by 15 mm
* Milling: LAP is available for slabs from 30 mm and for orders over 2000 m2, TAG for slabs from 40 mm